New Distribution Board Metering Solutions

Eaton’s Memshield 2 meter packs provide simple integration with matched aesthetics.

 The Feature Packed Eaton Meter Pack
 “New” Metering Solutions – Meter Pack Assemblies
 “New” Metering Solutions – Type A Meter Pack Assemblies
 Contact Details



The Feature Packed Eaton Meter Pack


BMMPCT200
Eaton’s Memshield 2 meter packs provide simple integration with matched aesthetics. The BMMPCT200 employs a multi-function, DIN rail mounted meter to measure electrical parameters on LV supplies to TPN Distribution Boards. It can also be used to meter single-phase loads. The unit is supplied complete with CT’s and wiring terminals. This version is suitable for 100A – 200A applications and as well as a pulsed output for kWh, the meter can be used to monitor other parameters, including line voltage and current.
Electrical connection to the associated Distribution board does not occupy any of the outgoing circuits.


BMMPDC100
The BMMPDC100 is supplied as a 100A direct connection solution, not requiring CT’s. Cabling is simple and the meter provides a pulsed output for kWh. The meter is an OFGEM Approved and certified unit,
providing clear kWh information.


BMMPSL125
shown with std B boards fitted
Double meterpack for mounting below two standard TPN distribution boards. Facilitates separate monitoring of “small power” and “lighting” from one main supply.


AMMP65
For single phase AM boards, a 65A meterpack provides simple integration. Amps, kW, kWh, kVar and kVarh pulsed output. MID compliant. See page 18 for single phase AM boards with factory fitted meters, including split power and lighting boards.


 Further Memshield 2 Information (PDF format)
 Contact Details


TopHome

 

“New” Metering Solutions
Meter Pack Assemblies


BMMPCT200


BMMPSL125
shown with std B boards fitted
   
Eaton’s Memshield 2 meter packs provide simple integration with matched aesthetics. Split Metering for separate small Power and Lighting has been added to the range to meet the needs of the L2 regulations introduced in England and Wales in 2006. The meters provide a pulsed output for kWh and display other useful parameters, including Line voltage and current.


Description

Rating

Quantity per carton

Eaton
List No.

100A direct connection, OFGEM approved meter

100A

1

BMMPDC100

125A split load meter pack

125A

1

BMMPSL125*

200A multi-function

200A

1

BMMPCT200

200A multi-function MID approved meter

200A

1

BMMP200MID
* Twin meter pack with 125A main switch disconnector fitted to supply two seperate type B boards (ordered separately).

 Further Memshield 2 Information (PDF format)
 Contact Details


TopHome

 

“New” Metering Solutions
Type A Meter Pack Assemblies

   
Eaton’s Memshield 2 meter packs provide simple integration with matched aesthetics. Split Metering for separate small Power and Lighting has been added to the range to meet the needs of the L2 regulations introduced in England and Wales in 2006. The meters provide a pulsed output for kWh and display other useful parameters, including Line voltage and current.

Description

Rating
(A)

Outgoing
Ways

QPC

Eaton
List No.

Meterpack for SPN type A

65A

-

1

AMMP65

9 way SPN type A metered board

65A

9

1

AM9M

12 way SPN type A metered board

65A

12

1

AM12M

6 + 6 way SPN type A Split metered board

65A

12

1

AMSL66M * †

8 + 4 way SPN type A split metered board

65A

12

1

AMSL84M *
* Two pulse outputs as standard.
Add suffix ‘B’ for modbus version, e.g. AM12MB.

 Further Memshield 2 Information (PDF format)
 Contact Details


TopHome


 






Telephone:

08700 545 333

Facsimile:

08700 540 333

Address:

Eaton MEM, Reddings Lane,
Birmingham B11 3EZ - United Kingdom
 E-mail: ukcommorders@eaton.com