IP Ratings (Degrees of Ingress Protection)
 Circuit Breaker Protection
 RCD's and Modular Contactors
 Circuit Breaker Data
 HRC Fuselink Protection
 Selecting the Correct Motor Starter
 Home Page

 

IP Ratings (Degrees of Ingress Protection)
The IP (Ingress Protection) rating system provides a means of classifying the degrees of protection from foreign bodies and liquids afforded by electrical equipment and enclosures.
The system is set in a number of British and European standards. These include BS EN 60529:1992 (IEC 60529:1989) Classification of Degrees of Protection by enclosures, BS 60947-1:1992 (IEC 144:1963) Specification for Degrees of Protection of Enclosures of Switchgear and Control Gear for Voltages up to and Including 1000V AC and 1200V DC.

 More about IP Ratings (Degrees of Ingress Protection)


TopHome

 

Circuit Breaker Protection
Highly detailed information regarding the protection of circuits using circuit breakers.
  • Protection of cables
  • Types of discrimination
  • Back-up protection
  • Fuse data for back-up
  • Prospective fault current
  • Current discrimination
  • Prospective fault level to which back-up is achieved
  • Thermal de-rating
  • Protecting lighting circuits with MCBs
  • D.C. applications of MCBs and MCCBs
  • Motor circuit protection
  • Transformer protection

 More about Circuit Breaker Protection


TopHome

 

 

RCDs and Modular Contactors
Details of trip current ratings, RCD applications, trouble shooting, shock hazard information and modular contactors.
  • RCD selection criteria & operating principles
  • Operating characteristics
  • Shock hazard curves
  • RCD trouble shooting
  • Causes of spasmodic tripping
  • Modular contactors

 More about RCDs and Modular Contactors


TopHome

 

Circuit Breaker Data
Maximum earth loop impedance, disconnection time/current data and maximum let through energy data for MCBs and MCCBs.
  • Maximum earth loop impedance Zs (OHMS)
  • Disconnection time/current data
  • Maximum let through energy

 More about Circuit Breaker Data


TopHome

 

HRC Fuselink Protection
The leading edge of HRC fuselink design. Describes in detail everything you would need to know about using Eaton MEM HRC fuselinks.
  • Features
  • Cable protection
  • Protection against electric shock
  • High ambient air temperature
  • Transformer, fluorescent lighting circuits
  • Capacitor circuits
  • Discrimination between fuselinks
  • Back-up protection
  • Motor circuit protection
  • Co-ordination with short circuit protective devices
  • Type 2 co-ordination

 More about HRC Fuselink Protection


TopHome

 

Selecting the Correct Motor Starter
Ratings from 16A up to 1600A covering 2 pole up to 8 pole versions, with a choice of enclosures to suit any application.
  • A choice of enclosures
  • Ratings from 16A to 1600A
  • Ingress protection IP52/65
  • Comply with BS EN 60947 and IEC 60408

 More about Selecting the Correct Motor Starter


TopHome

 

 